RP-HPLC METHOD FOR SIMULTANEOUS ESTIMATION OF RITONAVIR, OMBITASVIR AND PARITAPREVIR IN TABLET DOSAGE FORMS AND THEIR STRESS DEGRADATION STUDIES

Authors

  • SYED IBRAHIM BAJE PG Department of Chemistry, JKC College, Acharya Nagarjuna University, Guntur, A. P.,
  • B. JYOTHI Department of Chemistry, Swarna Bharathi Institute of Science and Technology, Khammam, Telangana
  • N. MADHAVI PG Department of Chemistry, JKC College, Acharya Nagarjuna University, Guntur, A. P.,

DOI:

https://doi.org/10.22159/ijap.2019v11i2.28141

Keywords:

Ombitasvir, Ritonavir, Paritaprevir, RP-HPLC, ICH guidelines

Abstract

Objective: The objective of the present study was to develop and validate a novel reverse phase high performance liquid chromatographic (RP-HPLC) method, for simultaneous determination of ritonavir (RIT), ombitasvir (OMB) and paritaprevir (PAR) in bulk mixtures, and in tablets.

Methods: Determination of the drugs ritonavir (RIT), ombitasvir (OMB), and paritaprevir (PAR), was carried out applying Hypersil BDS C18 column (250 mm X 4.6 mm i.e., 5 µm particle size), with photodiode array detector at λmax of 254 nm. The mobile phase applied for the current study composed of two solvents, i.e. A (0.01N % w/v potassium di-hydrogen orthophosphate buffer, pH 3.0 adjusted with dilute orthophosphoric acid) and B (acetonitrile). The mobile phase was pumped at a flow rate of 1.0 ml/min in the isocratic mode. The validation study with respect to specificity, linearity, precision, accuracy, and robustness, limit of detection (LOD) and limit of quantification (LOQ) was carried out employing the ICH guidelines.

Results: Ritonavir, ombitasvir, and paritaprevir showed linearity of response between 12.5-75 μg/ml for ritonavir, 3.125-18.75 µg/ml for ombitasvir and 18.75–112.5 µg/ml for paritaprevir, with a correlation coefficient (R2) 0.999, 0.999,0.999 for RIT, OMB, and PAR respectively. The % recovery obtained was 99.82±0.14 % RIT, OMB 100.03±0.96 % and for 99.96±0.26 % PAR. The LOD and LOQ values for RIT, OMB, PAR were obtained to be 0.02, 0.019and0.02, µg/ml and 0.07, 0.06 and 0.07 µg/ml, respectively. The method also exhibits good robustness for different chromatographic conditions like wavelength, flow rate, mobile phase, and injection volume.

Conclusion: The method was successfully employed, for the quantification of RIT, OMB, and PAR, in the quality control of in-house developed tablets, and can be applied for the industrial use.

Downloads

Download data is not yet available.

Published

07-03-2019

How to Cite

BAJE, S. I., JYOTHI, B., & MADHAVI, N. (2019). RP-HPLC METHOD FOR SIMULTANEOUS ESTIMATION OF RITONAVIR, OMBITASVIR AND PARITAPREVIR IN TABLET DOSAGE FORMS AND THEIR STRESS DEGRADATION STUDIES. International Journal of Applied Pharmaceutics, 11(2), 193–210. https://doi.org/10.22159/ijap.2019v11i2.28141

Issue

Section

Original Article(s)