SIMULTANEOUS DETERMINATION OF NITRITE AND NITRATE BY ULTRA-PERFORMANCE LIQUID CHROMATOGRAPHY IN RAT PLASMA

Authors

  • Aslam Burhan 1Department of Pharmacology, Maliba Pharmacy College, UKA Tarsadia University, Maliba Campus, Gopal Vidyanagar, Bardoli-Mahuva Road, Tarsadi, Taluka Mahuva, Surat, Gujarat-394350, India
  • Bhavin Vyas

Keywords:

UPLC, PDA, Nitrite, Nitrate, NO, Simultaneous determination of nitrite and nitrate

Abstract

Objective: To develop an ultra- performance liquid chromatography (Acquityâ„¢ UPLC) method for simple, fast, accurate and simultaneous determination of nitrite and nitrate ions as stable forms of nitric oxide (NO) production in rat plasma.

Methods: The ion-pairing Acquity™ UPLC method with reverse phase BEH C18 column was used along with photodiode array (PDA) UV-Vis detector to separate and detect nitrite and nitrate ions at an absorbance of 212 and 208 nm, respectively. Due to small particle size (1.7 µm) of the BEHC18 column, a narrow peak was achieved with an improved sensitivity and separation at the cost of pressure. The anions were analyzed in ultra-filtered deproteinized rat plasma sample (10 kDa, cut-off).

Results: The UPLC bioanalytical method was linear (r=0.9998, 0.9988) over wide ranges of 4-500 µM (nitrite) and 6-400 µM (nitrate) concentration. The most important advantages of the present method are; short time run time, no sample pre-treatment (unlike enzymatic reaction and pre-column treatment), low sample volume and simultaneous estimation of nitrite and nitrate in rat plasma.

Conclusion: It was concluded that the developed UPLC method for determination of simultaneous nitrite and nitrate in rat plasma was rapid, sensitive, accurate and linear over the wide ranges of concentration. This method can be used for simultaneous determination of nitrite and nitrate in rat plasma with various advantages over the reported methods.

Keywords: UPLC, PDA, Nitrite, Nitrate, NO

Downloads

Download data is not yet available.

References

Jobgen WS, Jobgen SC, Li H, Meininger CJ. Analysis of nitrite and nitrate in biological samples using high-performance liquid chromatography. J Chromatogr B: Anal Technol Biomed Life Sci 2007;85:71-82.

Smith CCT, Stanyer L, Betteridge DJ. Evaluation of methods for the extraction of nitrite and nitrate in biological fluids employing high-performance anion-exchange liquid chromato-graphy for their determination. J Chromatogr B: Anal Technol Biomed Life Sci 2002:201-9.

Ueda T, Maekawa T, Sdamitsu D, Oshita S, Ogino K, Nakamura K. The determination of nitrite and nitrate in human blood plasma by capillary zone electrophoresis. Electrophoresis 1995;16:1002-4.

Jedlickova V, Paluch Z, Alusik S. Determination of nitrate and nitrite by high-performance liquid chromatography in human plasma. J Chromatogr B: Anal Technol Biomed Life Sci 2002;780:193-7.

Romitelli F, Santini SA, Chierici E, Pitocco D, Tavazzi B, Amorini AM. Comparison of nitrite/nitrate concentration in human plasma and serum samples measured by the enzymatic batch Griess assay, ion-pairing HPLC and ion trap GC-MS: the importance of a correct removal of protein in the Griess assay. J Chromatogr B: Anal Technol Biomed Life Sci 2007;851:257-67.

Tsikas D. Analysis of nitrite and nitrate in biological fluids by assays based on the griess reaction: appraisal of the griess reaction in the L-arginine/nitric oxide area of research. J Chromatogr B: Anal Technol Biomed Life Sci 2007;851:51-70.

http://www.sigmaaldrich.com/etc/medialib/docs/Sigma/Datasheet/6/23479dat.Par.0001.File.tmp/23479dat.pdf. [Last accessed on 10 Dec 2015].

Published

01-06-2016

How to Cite

Burhan, A., and B. Vyas. “SIMULTANEOUS DETERMINATION OF NITRITE AND NITRATE BY ULTRA-PERFORMANCE LIQUID CHROMATOGRAPHY IN RAT PLASMA”. International Journal of Pharmacy and Pharmaceutical Sciences, vol. 8, no. 6, June 2016, pp. 294-6, https://journals.innovareacademics.in/index.php/ijpps/article/view/10629.

Issue

Section

Short Communication(s)